Home » Research Archive » 1995-1999 » View Cart | My Account   

Currencies

Reusability of avidin-biotinylated immunoglobulin Y columns in immunoaffinity chromatography.

Kim HO, Durance TD, Li-Chan EC
Anal Biochem 1999 Mar 268:383-97

Abstract
Reusability of avidin-biotinylated IgY columns for immunoaffinity chromatography was examined by repeated use and regeneration. An enzyme-linked immunosorbent assay-elution assay using CovaLink NH microtiter plates was used to find the optimal conditions for regeneration of columns. Actigel avidin-biotinylated IgY column retained about 90% of its initial IgG binding capacity after 50 cycles, with 0.1 M glycine-HCl buffer, pH 2.8, as eluent, requiring no regeneration. However, IgG binding capacity of UltraLink avidin-biotinylated IgY column gradually decreased to 75 and 65% after 10 and 20 cycles, respectively, with the commercial eluent, Actisep. Results from the CovaLink NH system agreed with those from UltraLink avidin-biotinylated IgY columns. The UltraLink avidin-biotinylated IgY column was regenerated twice, by applying 8 M guanidine-HCl, pH 1.6, to dissociate biotinylated IgY antibodies from the column. About 40 and 25% of IgG binding capacities remained after the first and second regeneration. By applying new biotinylated IgY to the treated columns, about 95 and 90% of the initial IgG binding capacity before any treatment were recovered. These results demonstrated that avidin-biotinylated IgY columns are reusable with or without regeneration depending on the avidin-immobilized matrix.

 
Print This Page